Installation

Safety warnings for kitchen unit installer

When used as an extractor unit, the hood must be fitted with a 100 or120mm diameter hose.

If the fumes must be forced out through the wall, you must obtain a MKZ sizable wall exhaust pipe (with external exhaust and air intake), E-Nr.- 610 899 004 (Ø 120 mm) which is one of our optional parts.

When installing the hood, make sure you respect the fol- lowing minimum distance from the top edge of the cooking hob/ring surfaces:

Electrical

650 mm

Gas hob

700 mm

Electric cooker

685 mm

Gas cooker

787 mm

The hood cannot be connected to flues of other appliances that run on energy sources other than electricity.

The air outlet must not be connected to chimney flues or com- bustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed.

It is advisable to apply for authorization from the relevant controlling authority when connecting the outlet to an unused chimney flue or combustion gas duct.

The air outlet installation must comply with the regulations laid down by the relevant authorities.

When the unit is used in its extractor version, a sufficiently large ventilation hole must be provided, with dimensions that are approximately the same as the outlet hole.

National and regional building regulations impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room.