This appliance must be connected to a cold water supply.
1. Open the porthole and extract the inlet hose.
2. Connect the hose with the angled connection to the machine.
Important!
Do not place the inlet hose downwards. Angle the hose to the left
or right depending on the position of your water tap.
3. Set the hose correctly by loosening the
ring nut. After positioning the inlet hose, be
sure to tighten the ring nut again to prevent
leaks.
4. Connect the hose to a tap with a 3/4”
thread.
Always use the hose supplied with the appli-
ance.
Installation should comply with local water authority and building reg-
ulations’ requirements. A minimum water pressure of 0.05 MPa (0.5 bar)
is required for safe operation of the appliance.
If you cannot make the cold water connec-
tion direct from the rising mains, you may
be able to operate the appliance from your
cold water storage system. There should be
a minimum distance of 5.02m (16.5 ft)
between theappliance’s inlet and the bot-
tom of the water storage tank.
Aqua Stop
The inlet hose is provided with a water stop device, which protects
against damage caused by water leaks in the hose which could develop
due to natural ageing of the hose. This fault is shown by a red sector in
the window „A”. Should this occur, turn the water tap off and refer to
your Service Centre to replace the hose.
Water drainage
This appliance is designed to be permanent-
ly plumbed into your home's drainage sys-
tem using one of the following methods.
1. Into a drainage standpipe.
Firstly form a hook in the end of the drain
hose using the “U” piece” supplied.
44
Installation
HEC0006
P1199
U piece
supplied
132978470 UK.qxd 21/02/2007 14.33 Pagina 44