Wall unit mounting - Fig. 7

Position the template on the wall (1) and mark the position, and drill

(2)the holes (2 x Ø 8 mm).

Mount the two wall plugs with the hooks (3).

Hang the hood on the hooks and level it with the adjustment screws

Remove the grease filters (5) and mark for the two screws (6). Remove the hood and drill the holes (2 x Ø 8 mm).

Insert the rawl plugs (7) and hang the hood on the wall again. Adjust it with the screws (8) and secure it with the screws (9).

Mount the chimney support (10) with the wall plugs (9) and the screws (11). Be careful that it is centered over the hood and horizontally aligned.

Extractor version (S): Connect a tube between the hood air outlet and the wall or roof exhaust channel. Fix it with the tube clamps supplied.

Filter version (K): Mount the deflector with the two screws supplied (2,9x13 mm) (13).

Make the electrical connection (14) (see previous page)

Place the chimney (15) and fix it to the top chimney support with the two screws (16) supplied (2,9x6,5 mm). Lower the bottom part of the chimney (17) and fasten it to the top of the hood with two screws, supplied (18) (2,9x6,5 mm).

15

Page 15
Image 15
AEG 8290 D, 8361 D, 8391 D, 8260 D, 8390 D, 8190 D, 8360 D installation instructions Wall unit mounting Fig