AEG DD 8891, DD 8990 short and straight outlet hose keep bends in outlet hose to a minimum

Models: DD 8625 DD 8821 DD 8891 DD 8665 DD 8695 DD 8861 DD 8990

1 21
Download 21 pages 11.76 Kb
Page 4
Image 4
-short and straight outlet hose

The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed.

The air outlet installation must comply with the regulations laid down by the relevant local authorities.

When the unit is used in extraction mode, a sufficiently large ventilation hole must be provided, with dimensions that are approxi- mately the same as the outlet hole.

National and regional building regulations impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room.

Hoods can only be used safely with appliances connected to a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approxi- mately 500-600 cm2 large to avoid the possibility of a depression being created during operation of the hood.

If you have any doubts, contact the relevant controlling authority or building inspector’s office.

Since the rule for rooms with fuel burning appliances is “outlet hole of the same size as the ventilation hole”, a hole of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood.

If the hood is used in its recirculation mode, it will operate simply and safely in the above conditions without the need for any of the aforementioned measures.

When the hood is used in its extraction mode, the following rules must be followed to obtain optimal operation:

-short and straight outlet hose

-keep bends in outlet hose to a minimum

-never install the hoses with an acute angle, they must always follow a gentle curve.

-keep the hose as large as possible (preferably the same diameter as the outlet hole).

-the length should be no more than:

3 metres with one 90° bend

2 metres with two 90° bends

Bends of more than 90° will reduce the efficiency of the hood and reduce the airflow.

Failure to observe these basic instructions will drastically reduce the performance and increase the noise levels of the extractor hood.