4.
Remove the inlet hose behind the
appliance.
5.
Clean the filter in the valve with a stiff
brush or a towel.

90˚

6.
Install again the inlet hose. Make sure
that the couplings are tight to pre-
vent leakages.
7.
Open the water tap.
EMERGENCY DRAIN
Because of a malfunction, the appliance
cannot drain the water.
If this occurs, do steps (1) through (3) of
'To clean the drain filter'.
If necessary, clean the filter.
Put the drainage duct back and close the
drain filter flap.
FROST PRECAUTIONS
If the appliance is installed in an area
where the temperature can be less than 0
°C, remove the remaining water from the
inlet hose and the drain pump.
1.
Close the water tap and disconnect
the inlet hose.
2.
Put the end of the inlet hose in a con-
tainer and let the water flow out of
the hose.
3.
Do the Drain programme and let it
operate until the end of the cycle.
4.
Turn the programme knob to Stop to
disconnect the appliance from the
power supply.
5.
Disconnect the appliance.
WARNING!
Make sure that the temperature is
more than 0 °C before you use the
appliance again.
The manufacturer is not responsi-
ble for damages caused by low
temperatures.
ENGLISH