What to do if ...

What to do if ...

Malfunction

Possible cause

Remedy

The appliance is over-

The temperature has been

Temporarily select a higher

cooling.

set too low.

temperature setting.

 

Temperature is not properly

Please refer to the section

 

adjusted.

"Temperature Adjustment".

 

Door was open for a long

Only leave the door open

The freezer compartment

time.

as long as necessary.

Within the last 24 hours a

 

temperature is insufficient.

Press FROSTMATIC button.

 

large quantity of warm

 

foods were loaded.

 

 

Appliance is next to a

Please refer to the section

 

source of warmth.

"Installation Location".

 

 

 

Interior illumination does

Light bulb is defective.

Please refer in this chapter

not function.

under "Replace light bulb" .

 

 

 

Carefully warm the door

 

 

seal with a hand-held hair

 

 

dryer at those points which

Accumulation of frost at

Door is not properly sealed

are not airtight (no warmer

(perhaps after reversing

than approx. 50°C). At the

the door seal.

the door).

same time, shape the

 

 

 

warmed door seal by hand,

 

 

so that it is again properly

 

 

seated.

 

Appliance is not level.

Readjust the front levelling

 

feet.

 

 

 

Appliance is in contact

Push appliance away a

Unusual noises.

with wall or other objects.

short distance.

 

 

 

A part at the back of the

 

 

appliance, e.g. a tube, is in

Bend this part away

 

contact with another

carefully if necessary.

 

appliance part or the wall.

 

The compressor does not

 

 

start immediately after

This is normal, no error has

The compressor starts after

pressing the FROSTMATIC

occurred.

a period of time.

button, or after changing

 

 

the temperature setting.

 

 

 

 

 