Problem

Possible cause

Solution

The compressor oper-

The thermostatic control is set incor-

Set the thermostat knob to a position

ates continually.

rectly.

that gives higher temperature.

 

Doors are not shut properly or do not

Check if the doors close well and the

 

close tightly.

gaskets are unhurt and clean.

 

Products in big quantity to be frozen

Wait some hours and then check the

 

were put in.

temperature again.

 

Too warm food was put in.

Put food at max. room temperature.

The appliance does

Plug is not connected to the mains

Check the connection.

not work at all.

socket properly.

 

Neither cooling, nor

The fuse burnt out.

Change the fuse.

lighting works.

The thermostatic control is not on.

Start the appliance according to

 

 

 

instructions in chapter 'Putting it into

 

 

use'.

 

Electrical network broke down.

Get an electrician to check it.

 

 

The appliance is

The appliance is not supported proper-

Check if the appliance stands stable

ly.

(all the four feet should be on the

noisy.

 

 

floor).

 

 

 

 

 

 

 

 

Inasmuch as the advice does not lead to result, call the nearest Service Force Centre.

26

Page 26
Image 26
AEG 200372733, S 75400 KG8 manual Thermostatic control is set incor