Adjusting the level of conductivity

Adjusting the level of conductivity

Water contains, a variable quantity of limestone and mineral salts of which quantities vary according to geographical locations thus vary- ing its conductivity values.

Relevant variations of the conductivity of the water compared to those prefixed by the factory could slightly influence the residual humidity of the laundry at the end of the cycle.

Your dryer allows you to regulate the sensitivity of the drying sensor based on conductivity values of the water by using the following procedure.

Procedure:

Turn the programme selector dial to switch on the appliance

In selection mode press simultaneously the buttons 3 and 6 until «C0» appears on the digits.

1

2

3

4

5

6

Adjusting the level of conductivity:

Press the button 5 sequentially: the level of conductivity is indicated by the lighting of the horizontal hyphens.

DISPLAY

Conductivity degree

Approximative value

 

 

µS/cm (25°C)

C0 -

Low

< 300

 

 

 

 

C0 -

Medium

300 - 600

-

 

 

C0 -

High

> 600

-

Normally, the appliance is factory-set to the highest level; howe- ver, certain models may be configured differently.

Memorizing the new setting:

Simultaneously press down the buttons 3 and 6 until the previous drying cycle time appears again on the display and the buzzer sounds.