4.9 CoEx® Espresso Brewer Unit - Weekly Cleaning Procedure

Operators Manual

5.Carefully remove the brewer waste container from the machine and empty the contents. Push up and remove the waste chute (a) from the machine.

Wash both the waste container and chute thoroughly and if necessary sanitise using the diluted bactericidal cleaning solution. Rinse in clean water.

Dry both components using a clean, dry cloth and refit to the machine.

a

N.B. Every time that the brewer waste container is emptied the waste counter must be reset. Restore power to the machine using the safety key and press button 12 on the service keypad. Two audible bleeps confirm that the counter has been reset to zero.

6.Refit the CoEx® brewer unit into the machine. Slide the unit into place until it ‘clicks’ into position. Refit the coffee dispense pipe to the brewer outlet as shown.

Ensure that both the fresh bean container and fresh ground coffee canister are filled with correct product. Refill if necessary following the procedures outlined on pages 22 and 23.

4.9 CoEx® Espresso Brewer Unit - Weekly Cleaning Procedure

The following procedure must be carried out on a weekly basis. Proceed as follows:-

1.Open the front door of the machine and insert the safety key to restore power to the machine.

Caution: Ensure that a suitable container is placed under the dispense position. Keep hands away from the dispense area whilst the cleaning cycle is in operation.

2.Press and release button 11 on the service keypad. The LCD will display the message ‘Please Place Cleaning Tablet in Brewer’.

Take one cleaning tablet (supplied in packs of 30 - CMS part no. ZC10598000) and place it into the brewer piston chamber as shown.

29