Operators Manual

2.Freshbrew & Espresso Machines: Evolution machines fitted with a paperless freshbrew brewer or CoEx® brewer must be connected to the water supply via a water filter. This filter must be of food grade quality and able to remove temporary hardness (scale), heavy metals (lead, copper, iron, cadmium), chlorine

and any organic pollutant’s/discolouration. Crane Merchandising Systems recommend and supply the Brita AquaQuell water filter.

Warning! If the machines indicated above are connected to the water supply and used without a water filter as specified, the warranty will be void.

3.Connect the flexi-hose supplied with the machine to the stopcock ensuring that the seal supplied is fitted correctly. Flush the system (several gallons) before connecting the machine.

3.Connect the hose to the inlet valve located on the rear of the machine. Ensure that the seal is correctly fitted. Ensure that all water supply fittings are tight.

4.Turn on the water supply at the stop tap and check for leaks. Prime the water filter (where fitted) following the instructions supplied by the filter manufacturer.

2.3 Connecting the Electrical Supply

Safety First! The machine must be earthed. On no account should it be earthed only to the water supply pipe.

The machine must be connected to a 230 Volt 50Hz 13 amp fused switched socket outlet, installed to the latest edition of the IEE regulations, using a 3 pin BS approved 13 amp fused plug.

Important: If the mains lead becomes damaged in any way it must be replaced by a special lead available from the manufacturer.

2.4 Commissioning Procedure

The following procedure must be carried out by a trained installation engineer before the machine can be used for the first time. Ensure that the electrical and water services to the machine are connected correctly. Check for leaks in the water supply.

1.Open the front door of the machine. Fit the door switch bracket to the door using the two screws provided. Ensure that the bracket will operate the door switch when the door is closed. Switch on the electricity supply.

2.Ensure that the waste bucket is fitted correctly. Clip the level detector and overflow pipes correctly onto the rim of the bucket.

8

Page 10
Image 10
Evolution Technologies PR10908000 manual Connecting the Electrical Supply, Commissioning Procedure