Operators Manual

N.B. Every time that the brewer waste container is emptied the waste counter must be reset. Restore power to the machine using the safety key and press button 12 on the service keypad. Two audible bleeps confirm that the counter has been reset to zero.

Close and lock the door.

4.8 CoEx® Espresso Brewer Unit - Daily Cleaning Procedure

1.Remove the coffee dispense pipe from the brewer outlet. Holding the unit as shown in the photograph, lift the green lever (a) and carefully pull the brewer unit out of the machine.

Fill a cleaning bucket with hot water and dilute the bactericidal cleaning agent in accordance with the instructions on the product packaging.

2.Carefully place the CoEx® brewer unit into the diluted bactericidal solution and clean the unit thoroughly. Ensure all coffee ground deposits are removed, paying particular attention to the area around the top of the piston and waste chute.

Remove the unit from the solution and rinse thoroughly with clean water. Dry the unit using a clean cloth or paper towels.

3.Remove the espresso coffee chute assembly (a). Unscrew the two knurled thumbscrews (b) and remove the coffee chute and coffee chute cover.

With a clean, dry brush clean the area around and under the coffee dispense outlets.

4.With a clean, dry brush wipe away any coffee deposits from both the coffee chute and cover mouldings.

Refit the coffee chute lid to the chute ensuring that the lugs on the cover fit securely into their mounting holes.

Refit the assembly to the machine and secure using the two knurled thumbscrews.

b

a

28

Page 30
Image 30
Evolution Technologies PR10908000 manual CoEx Espresso Brewer Unit Daily Cleaning Procedure