Operators Manual
1.From the Main Menu press the ▼ (down) key until Timed Events is highlighted
| then press the ↵ (Edit) key. Once in the Timed |
| Sanitation Events Menu | |||
| Events menu press the ▼ (down) key to highlight | 2 | Timed | Off | ||
| Sanitation Events Menu then press the ↵ | (Edit) | 3 | Timed | Off | |
| 4 | Timed | Off | |||
| key. Press the ▼ (down) key until the first Post | |||||
| 5 | Timed | Off | |||
| Vend event is highlighted. The LCD will display | 6 | Timed | Off | ||
| 7 | Post Vend | Off | |||
| the screen as shown. |
| ||||
|
|
|
|
| ||
|
|
|
|
|
| |
2. | With Post Vend highlighted, press the ↵ | (Edit) |
| 7 |
| |
| key to access the 7 Post Vend sub menu. The | State |
| |||
| Event Type |
| ||||
| LCD will change and display the screen as shown. |
| ||||
| Delay |
| ||||
| By default the current State is set to Off as |
|
|
| ||
| indicated by the status line at the bottom of the |
| Off |
| ||
| screen. |
|
|
|
| |
|
|
|
| State |
| |
3. | Press the ↵ | (Edit) key to access the State sub |
|
| ||
| menu. Using the ▼ (down) key, set the state to |
| Off |
| ||
|
| On |
| |||
| On (indicated by the filled radio button). Press |
|
| |||
|
|
|
| |||
| the ↵ (Edit) key to return to the 7 (Post Vend) |
|
|
| ||
| screen. Verify that the status line confirms the |
|
|
| ||
| State is set to On. |
|
|
|
| |
4. | Press the ▼ (down) key to highlight Event Type. |
| 7 |
| ||
| By default the event is set to Timed as indicated | State |
| |||
| by the text | displayed in the status line | at the | Event Type |
| |
| Delay |
|
bottom of the screen. Therefore it is not necessary for the operator to enter this sub
menu.
Post Vend
5.Press the ▼ (down) key to highlight Delay. The status line indicates the factory
default delay which is set to 0.1hrs (6 minutes). To change the value so that the machine will self clean 12 minutes after a drink is vended press the
↵(Edit) key to access the Delay sub menu. The
LCD will display the screen as shown. Using the drink selection keypad, press the sequence
Press the ↵ (Edit) key and verify that the status line confirms that Delay (when highlighted) is set to 0.2hrs.
6.Press the X (Exit) key three times to return to the Timed Events Menu. Using the sequence described above the operator can quickly and easily set up additional post vend sanitation event periods for the machine if required.
59