18 www.aeg.com

Problem1)

Possible cause

Remedy

 

The loading door is opened.

Close the loading door.

 

The On/Off button was not

Push the On/Off button.

 

pushed.

 

 

 

The Start/Pause button was not

Push the Start/Pause button.

 

pushed.

 

 

The appliance is in the standby

Push the On/Off button.

 

mode.

 

 

 

Incorrect programme selection.

Do the selection of the applica-

 

ble programme. 2)

 

The filter is clogged.

Clean the filter. 3)

 

The Dry Plus function was in

Change the Dry Plus function

 

to the moderate or maximum

 

minimum mode.

 

mode.

 

 

Unsatisfac-

The condenser is clogged.

Clean the condenser. 3)

tory drying

Too high volume of the load.

Obey the maximum load vol-

results.

ume.

 

 

 

The airflow grill is clogged.

Clean the airflow grill in the

 

bottom of the appliance.

 

 

 

Dirt on the inner surface of the

Clean the inner surface of the

 

drum.

drum.

 

Too high water hardness.

Set applicable water hard-

 

ness4).

 

 

The door

The filter not locked in the po-

Put the filter in the correct posi-

sition.

tion.

does not

The laundry is locked between

Put the load correctly in the

close.

 

the door and the seal.

drum.

 

You try to change the pro-

Turn the tumble dryer off and

 

gramme or the function after

Err (Error)

on. Make the new selection.

the start of the cycle.

on the dis-

 

 

The function you try to activate

 

play.

Turn the tumble dryer off and

is not applicable with the selec-

 

on. Make the new selection.

 

ted programme.

 

No drum

Defective drum light.

Contact the service centre to

light 5)

replace the drum light.

 

Abnormally

The time to end is calculated

The automatic procedure —

elapsing

on the basis of the volume and

this is not the appliance mal-

time on the

dampness of the laundry.

function.

display.)

 

 

Programme

The water container is full.

Drain the water container3)

,

inactive.

push the Start/Pause button.

 

 

 

 

 

Page 18
Image 18
AEG T76280AC user manual Inactive Push the Start/Pause button