D. TO REMOVE HANDRAIL (SEE FIG. 24)
1. Loosen 2 grub screws, one at each end of hand rail (See Fig. 24) using 2 1/2 mm socket
key.
2. Slide handrail forwards, off locating studs.
E. TO REMOVE TIMER
1. Isolate from electric supply.
2. Proceed as ‘TO REMOVE HOTPLATE CASTINGS’.
3. Proceed as ‘TO REMOVE FACIACASTING’.
4. With the facia casting removed, remove the four fixing screws which clamp the timer to
the inside of the facia casting. The timer assembly can now be removed.
5. Depress the tabs on the side of the casing and slide the timer out of the sheet metal
bracket.
6. Re-assemble in reverse order, making sure control buttons have clearance around them
when assembled with the glass facia panel.
47
Fig. 24 DESN 513525