AGA ELECTRIC RANGE (EC LM - 2 OVEN & EE LM - 4 OVEN) - OWNERS MANUAL
This appliance must be connected to a grounded, metallic, permanent supply or a grounding connector should be connected to the grounding terminal or wire lead on the appliance.
Failure to follow these instructions could result in death or serious injury.
●A
●A
●Local codes permit the use of a U.L. listed,
Wire sizes (COPPER WIRE ONLY) and connections must conform with the rating of the range
●The wiring diagram is located on the back of the L.H. door.
THIS APPLIANCE MUST HAVE THE FACILITY OF BEING COMPLETELY ISOLATED FROM THE ELECTRICITY SUPPLY.
THE APPLIANCE MUST BE COMPLETELY ISOLATED FROM THE ELECTRICITY SUPPLY BEFORE SERVICING.
WARNING
Electrical Grounding Instructions
This appliance is equipped with a grounding pin for your protection against a shock hazard and should be plugged directly
INSTRUCTIONS
Hand this Owners Manual to the user for retention and instruct in the safe operation of the appliance.
Also advise the user that, for continued efficient and safe operation of the appliance that servicing is carried out at intervals recommended by the Aga distributor.
ELECTRICAL TEST PROCEDURE
Final Electrical Test - Electric Voltage - Withstand Test
Procedure:
(Earth Appliance Test Simulation)
1.Select 1200 volts Flash Test on test equipment.
2.Plug in supply plug into the test equipment.
3.Depress the ‘Test Button' for 1 second.
4.A 'Pass' light will illuminate.
5.If the appliance fails this test,
6.Disconnect from the test equipment and connect range to its permanent supply.
7.A full load test will be performed using a clamp meter connected to the incoming supply. NOTE: The test results 10.5
file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS513307/EINS513307.htm (8 of 18)8/16/2006 9:18:22 AM