Agilent Technologies 89600 Operation, Basic operation, Sampling modes full rate and user rate

Models: 89600

1 24
Download 24 pages 49.2 Kb
Page 8
Image 8

4 Operation

4.1 Basic operation

Operation of the broadband VSA is substantially the same as that of the 89600 VSA. See the following sections for some differences or special configurations. There is an online Tutorial and Getting Started Guide under the Help/Roadmap toolbar in the 89600 software.

4.2 Sampling modes: full rate and user rate

Full rate mode

When the Sample Mode is set to full rate using the Utilities/Hardware/ADC1 /Agilent Acqiris One Channel Digitizer/Configure/Sample Mode/Edit menu path for the U1065A-001 or Utilities/Hardware/ADC1 /Agilent Acqiris Two Channel Digitizer/Configure/Sample Mode/Edit menu path for all the other models, the digitizer sample rate is fixed at the maximum for each digitizer model according to Table 4.

Table 4. Sample rates of Acqiris digitizers in full rate mode

Digitizer model

No. of channels

Full sample rate

U1066A-001 (DC440)

1

400 M

U1066A-001 (DC440)

2

400 M

U1066A-002 (DC438)

1

200 M

U1066A-002 (DC438)

2

200 M

U1065A-001 (DC222)

1

8 G

U1065A-002 (DC252)

1

8 G

U1065A-002 (DC252)

2

4 G

U1065A-004 (DC282)

1

8 G

U1065A-004 (DC282)

2

4 G

With the addition of the anti-alias lowpass filter described above, this mode is free of alias exposure zones. This means that no signal anywhere in the range of the VSA’s center frequency will alias upon the desired signal and corrupt the measurement.

There is a trade-off when using this mode. Although the digitizers have deep memories allowing long record lengths, if a longer Main Time (or Result Length for digital demodulation) is needed for more resolution in the frequency domain a different sample mode may be required. Go to the Configure menu, click on Sample Mode/Edit and select User Rate from the drop-down menu. The Main Time limit for any sample rate is shown in the operating region curves that appear in Appendix C.

NOTE: Any limitation to Main Time (or Result Length) will be indicated by the inability of the software to increase the Main Time or decrease RBW when Number of Frequency Points is increased.

8

Page 8
Image 8
Agilent Technologies 89600 manual Operation, Basic operation, Sampling modes full rate and user rate

89600 specifications

Agilent Technologies, a leading player in the test and measurement sector, has developed the 89600 VSA (Vector Signal Analysis) software, a powerful tool designed for a wide variety of signal analysis applications. This software is crucial for engineers and researchers developing and testing wireless communication systems, radar technologies, and other complex signal environments.

One of the main features of the Agilent 89600 is its capability to analyze both analog and digital signals with high precision and flexibility. It supports a broad range of modulation formats used in modern communication systems, including LTE, Wi-Fi, GSM, and many others. This extensive modulation support enables users to test their designs against industry standards and protocols, ensuring compliance and operational integrity.

The 89600 VSA software excels in its real-time analysis capabilities, which is critical for evaluating transient signal behavior and understanding time-varying signals. With its advanced algorithms and fast processing capabilities, users can perform real-time demodulation of complex signals, which is vital for debugging and optimizing communication systems. The software also supports offline analysis, allowing engineers to capture and analyze signals at their convenience.

Another standout characteristic of the 89600 software is its intuitive user interface, which streamlines the setup process and enhances user experience. The drag-and-drop functionality allows for easy configuration of measurement setups, while comprehensive visualization tools provide deep insights into the signal characteristics. Users can visualize modulation quality, spectral components, and error vectors through various graphical representations.

The software integrates seamlessly with Agilent's hardware spectrum analyzers and signal generators, offering a holistic solution for signal generation and analysis. It also supports a wide range of signal inputs, from hardware-based vector signal generators to recorded data files.

Moreover, the flexibility of the Agilent 89600 is enhanced through its modular architecture, which allows users to easily add new measurement capabilities via optional software packages. This adaptability ensures that the tool stays relevant as communication technologies evolve.

In summary, Agilent Technologies' 89600 VSA software combines advanced signal analysis capabilities with user-friendly features to provide a comprehensive solution for communication engineers. Its ability to handle multiple modulation formats, real-time analysis, and robust visualization tools makes it an essential resource for anyone involved in the development and testing of signal-based technologies.