7.For the standard setup, use the holes shown in the illustration. Other hole combinations allow different handle heights and hopper angles. Do not use holes in stand that are farthest apart as a combination - flow gate may not close completely.

Attach the stand to the hopper frame tube using two 1/4 x 1-1/2 in. bolts and nylock nuts. Attach the stand to the lower handle using two 1/4 x 1-1/2 in. bolts and nylock nuts. Tighten all four bolts to secure the stand.

See figure 4.

USE

1/4-20 NYLOCK

MIDDLE

NUT (E)

HOLE

 

9.Install a handle grip on each handle. See figure 6.

10.Attach the flow control lever to the bracket using one

1/4 x 3/4 in. bolt, nylon washer and nylock nut. Tighten carefully to allow the lever to move freely. Install the vinyl grip. See figure 6.

HANDLE

1/4-20 x 3/4 in.

GRIP (P)

HEX BOLT (C)

 

1/4 in. NYLON WASHER (G)

LEVER

GRIP (Q)

 

 

 

USE THIS

1/4-20

x 1-1/2 in.

HOLE

HEX BOLT (B)

FIGURE 4

8.Attach the two upper handles together with the flow control bracket as shown using three 1/4 x 2-1/2 in. bolts and nylock nuts. Do not tighten two bolts in flow control bracket. Tighten third bolt in upper handles. See figure 5.

1/4-20 x 2-1/2 in.

HEX BOLT (A)

1/4 in. WASHER (F) 1/4-20 NYLOCK

NUT (E)

FIGURE 5

1/4-20 NYLOCK

 

 

LEVER

NUT (E)

 

 

FIGURE 6

11.Attach the spring to the stainless steel pattern plate as shown. Attach the opposite end of the spring to the 1/8 in. hole in the flow control rod. Rotate the end of the rod into the flow control link. See figure 7.

SPRING

ANCHOR

HOLE

SPRING (L)

1/8 in. HOLE

FLOW

CONTROL

LINK

FIGURE 7