11
Connections
1CX1
1CX2
M1
M2
1MX1
1MX2
1MX3
2MX1
2MX2
2MX3
M3
M4
D1
D2
IP1
LAN
IP2 IP3
D3
D4
2CX1
2CX2
3CX1
3CX2
4CX1
4CX2
P1 P2 P3 P4 L1 L2 L3 L4 L5 L6 L7 L8
S1E S2 E S3E S4E
IS-RCU
MASTER STATION IS-SCU IS-IPC
DC48V
DOOR/SUB STATION
VIDEO/AUDIO
PA OUTPUT (600Ω)CONTACT INPUT
CHIME INPUT
(600Ω)
ETHERNET
VIDEO OUTPUT
CONTACT OUTPUT (AC/DC24V 0.5A)
B2B1 V1 V2
CAT5e/6
200m
(650')
CAT5e/6
200m
(650')
CAT5e/6
300m
(980')
CAT5e/6
300m
(980') 10m (33')
15m
(50')
200m
(650')
CAT5e/6
150m
(490')
Coax
15m (50')
NTSC
15m (50')
NTSC

*2 *3

*4

*1
D
C
2C
M
IP1 IP2 IP3MX1 MX2 MX3
Coax
CX1/IP1 CX2/IP2
PT
BNC
connector
BNC
connector
BNC
connector
BNC
connector
φ0.65-1.2mm
(22-16 AWG)
φ0.65-1.2mm
(22-16 AWG)
15m (50')
φ0.65-1.2mm
(22-16 AWG)
15m (50')
φ0.8-1.2mm
(20-16 AWG)
NP NP
P
P
2C
2C
2C

*5

NP
2C
φ0.65-1.2mm
(22-16 AWG)
15m (50')
P
2C
φ0.65-1.2mm
(22-16 AWG)
15m (50')
NP
2C
φ0.65-1.2mm
(22-16 AWG)
NP
2C
φ0.65-1.2mm
(22-16 AWG)
CAT5e/6 (x3)
CAT5e/6 (x3)
*1: This connection is needed when a PA ampli er that needs a trigger input is connected. (Up to AC/DC 24V 0.5A)

*2: This connection is needed when a sound source etc. that needs a trigger input is connected. (Up to AC/DC 24V 0.5A) Connect a timer to the

CONTACT INPUT terminals when an external sound source device (CD player etc.) that does not have a timer function is connected.

*3: This connection is needed when a sound source that has a trigger output is connected.

*4: Refer to the SETTING MANUAL for connection and settings.

*5: Do not install two power supplies in parallel to a single input. Be sure to connect a single power supply unit to a control unit.

*6: Do not use an external sound source as background music. If the background music is interrupted by another performance during chime paging,

the chime paging will not be restored after the performance ends.

*7: Outputs images only from a video door station connected to this unit.

*8: Output speci cations

Output method N/O or N/C dry closure contact

Voltage between

terminals

24V AC, 0.5A (resistive load)

24V DC, 0.5A (resistive load)

Minimum overload (AC/DC): 100mV, 0.1mA

NOTES:
Do not use the unoccupied terminals and ports for other purposes.
In order to prevent miswiring, label both ends of each cable with
the unit and terminal names to which they are to be connected.For connecting other manufacturer’s products, refer to the
instruction manuals for those products.The illustration of the unit’s front panel differs from the actual
one. This is for simplifying the connection diagram.

*9: Input speci cations

Input method N/O or N/C dry closure contact (start

signal only detection method)

Detection con rmation

time

100 ms or more

Contact resistance During N/O dry closure: Less than 700 Ω

During N/C dry closure: At least 4 k Ω

Terminal short current Less than 10 mA

Voltage between

terminals

Less than 5 V DC (when open between

terminals)

Monitor 1,
Recorder 1
Monitor 2,
Recorder 2
Door station
(IS-DV/IS-DVF/
IS-SS)
Power supply unit
(IS-PU-UL/IS-PU-S)
Master station
(IS-MV)
Contact output *8
(Electric door strike, strobe light, etc.)
PA output
(50mVrms, 600Ω)
PA ampli er
External sound
source such as
CD player, etc. *6
Chime input (50mVrms, 600Ω)
Contact input *9
Sensor, etc.
Room sub control unit
(IS-RCU)
Add-on control unit
(IS-SCU)
PC for setting
the system
Room sub station
(IS-RS)
IP control unit
(IS-IPC)
or
(non-shielded)
(non-shielded)
(non-shielded)
(non-shielded)
(non-shielded)
(non-shielded) (non-shielded)
AC
transformer
NP: Non-polarized
P: Polarized

*7 *7