1.The entry station has multiple call buttons with an associated directory card. Press the button of the person you wish to call.

2.The master station(s) will ring an electronic call tone as long as the call button on the entrance station is being held. (A chime will be heard when using the C-ML/A room stations.)

3.With CM-L/A and LEM-1DL/C Master Stations: Press TALK button to answer the call.

With LEF Master Stations: Select the station button with the lit LED to answer. If the LED has gone out (stays on for approx. 20 seconds), press the selector button assigned to the entry station.

4.At the inside station, press the TALK button to talk, and release to listen. The person at the entrance station speaks hands free.

5.When finished with the call, press the OFF button on the master station.

6.NOTE: If the "Occupied" lamp is on, the system is in use. Wait until the LED goes out, or determine if a master station has been left on unintentionally.

SPECIFICATIONS:

Power Source:

Provided from master station.

 

C-ML/A: 1 SKK-620 or 4 "C" batteries per master.

 

LEM-1DL/C: 1 PT-1210N per master.

 

LEF: 1 PS-12C per system.

Impedance:

20 ohms

Communication:

Hands free at entry station. Push-to-talk at master station.

Calling:

C-ML/A: 4-Stroke chime

 

LEM-1DL/C: Momentary call tone

 

LEF: Momentary call tone and LED, remaining lit for approx. 20 seconds

Wiring:

C-ML/A: 2 conductors homerun per station to entrance panel.

 

LEM-1DL/C: 2 conductors homerun per station to entrance panel.

 

LEF: 4 common (E, R, +, -) plus 1 individual per sub, looped; or 5 conductors homerun

 

to each master. Shielded cable is recommended.

 

Use Aiphone #822202 (2 conductor) or 822212 (12 conductor) for max. 8 station wiring.

Door Release Wiring:

2 conductors looped through stations to strike and strike power supply.

Wiring Distance:

C-ML/A: 245' with 22AWG; 590' with 18AWG.

 

LEF/LEM: 650' with 22AWG; 1,600' with 18AWG.

Aiphone Communication Systems

1700 130th Ave. N.E.

Bellevue, WA 98005

(425)455-0510 FAX (425) 455-0071

NOTE:

Only information concerning the GW-LE8 is shown here.

For complete wiring information, please see the appropriate system instructions.