English
3 WIRING
Insert wires securely into each terminal as shown.
DOOR 1Video door station
AIPHONE
#2 #1 |
Français
Nederlands
A1 A2
2
NP
DOOR 2
AIPHONE
(Audio only)
Setting is required. (Refer to section
A1 A2
2
NP
Optional call extension speaker
OP | 1 | E |
|
| 2 |
| NP | |
|
|
Door release
P
2
- + DC 18 V
Power supply +, - (DC 18 V)
|
| ||
230V AC | N |
| |
| L |
| |
IN 230V~ 50/60Hz NL |
|
| |
1A - + |
|
| |
- | 100V - 240V - | 18V DC | |
+ | 2 A | ||
18V DC 1 A | 50/60 Hz | ||
|
Release connector | (BR) | L | [1] | Door release | |
| |||||
| (RD) | L | |||
#1 |
|
| or | ||
(OG) | SW | [2] |
| ||
| (YE) | SW |
| ||
Option connector | (BR) | V + | [3] |
|
|
(RD) | V - |
|
| ||
|
|
|
| ||
| (OG) | b1 | [4] | ||
#2 | (YE) | b2 | |||
(GR) | E |
|
|
| |
| (BL) | PK |
|
|
|
| (PR) | FS |
| [6] | [5] |
| (GY) | KS | [7] | ||
|
| ||||
| (WH) | E |
|
| |
|
|
|
|
To prevent shorts, be sure to cut unused lead wires at the bottom and insulate the ends.
Control external devices connected with release connector and option connector.
[1]Door release output Setting is required. (Refer to section
Connect the brown and red wires from the release connector to the door release (or to the
[2]Options output
(AC/DC 24 V, 1.6 A N/O dry closure contact)
Door release | OP |
equivalent, requires a separate AC transformer. |
|
Run separate cables for audio/video and door |
|
release. |
|
Door release contact: AC/DC 24 V, 0.5 A |
|
(N/O dry closure contact L, L). |
|
2
NP
[3]Video signal output
(NTSC, 1
NOTES: When video signal is output to the external equipment, it may be possible to hear the buzz noise
[1] | from master station. Consult AIPHONE distributor. |
[4] Door |
[5] | |
| If the blue and white wires are shorted, |
| be operable. |
[6] | Foot switch input |
Optional selective door release |
|
| |
adaptor | L1 |
| |
Use |
| b1 | |
door release to 2 locations. | C1 | ||
L1 | b2 | ||
|
| L2 | b3 |
|
| L | |
|
| C2 | D1 |
|
| L2 | E |
|
| PT | D2 |
PT AC Transformer |
|
| + |
|
| – |
JF-2MED
Option connector
OG(b1)
YE(b2)
GR(E)
Release connector
BR(L)
RD(L)
DC 18V
+
–
Connect a | |
and white wires (N/O dry closure contact). | |
[7] External sensor input | Setting is required. (Refer to section |
|
| N/O dry closure contact |
| Input method | External sensor input |
|
| (start signal only detection method) |
| Detection confirmation time | 100 mS or more |
| Contact resistance | During dry closure: Less than 700 Ω |
PS18 | Terminal short current | Less than 10 mA |
| Voltage between terminals | Less than DC 20 V |
| (when open between terminals) |
- 4 -