IMPORTANT INSTRUCTIONS -

OPERATING MANUAL

Models B300, B500

Blower

 

 

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT

YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to person, including the following:

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO PERSON, OBSERVE THE FOLLOWING:

1.Read all instructions before installing or using range hood.

2.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

3.Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

4.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire- related construction.

5.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code authorities.

CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.

6.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

7.Refer to the instructions included with the Range Hood Canopy for additional safety information.

INSTALLATION INSTRUCTIONS

CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION.

WARNING: THIS BLOWER IS INTENDED FOR USE ONLY IN AIR KING PROFESSIONAL SERIES RANGEHOOD CANOPIES MARKED SUITABLE FOR USE WITH THIS BLOWER. DO NOT TO INSTALL IN ANY OTHER APPLICATION.

SECTION 1

Preparing for installation

NOTE: Before installing blower, make sure range hood canopy is properly installed and securely in place. See “Range Hood Mounting Instructions”.

1.Unpack blower from the carton and confirm that all pieces are present. In addition to the blower you should have:

8 - 8-32 Screws

8 - Washers

1 - Fuse

1 - Wire Harness

1 - Instruction/Safety Sheet

2.The installation of the blower is slightly different from one canopy height to another. For 18" high canopies proceed to Section 2, for 10" high canopies proceed to Section 3.

SECTION 2

Installation into 18" High Canopy

1.Lift blower up into the hood canopy and slide the keyhole slots in the blower mounting flange over the two studs of the hood. Slide the blower into place and tighten the hex nuts on the mounting stud while lining up the 8 holes in the blower mounting flange to the 8 screw studs of the hood (Figure 1).

Stud w/Hex Nuts

Screw Stud

Keyholes

Figure 1

SAVE THESE INSTRUCTIONS

111597002 New 3-07

www.airkinglimited.com

1 of 8

Page 1
Image 1
Air King B500 installation instructions Important Instructions Operating Manual, Read and Save These Instructions, Section

B300, B500 specifications

The Air King B500 and B300 are two of the standout models in the Air King line of ventilation products, specifically designed to meet the diverse needs of residential and commercial spaces. Both models bring innovative technologies and features that enhance air quality and energy efficiency.

The Air King B500 is known for its advanced airflow capabilities, offering an impressive CFM (cubic feet per minute) rating that ensures effective air movement in larger spaces. This model is equipped with a powerful motor that not only provides high performance but also operates quietly, making it ideal for use in homes, offices, and workshops. The B500 features a durable, corrosion-resistant housing, making it suitable for humid environments such as bathrooms or kitchens.

One of the most notable technologies in the B500 is its multi-speed settings, allowing users to customize the airflow to their specific needs. This flexibility is complemented by an easy-to-use control panel that provides quick access to speed adjustments and other functionalities. Additionally, the model incorporates a built-in timer, which enables users to set the ventilation to run for a predetermined period, ensuring efficient energy use.

Similarly, the Air King B300 offers an excellent balance of performance and efficiency. With a slightly lower CFM compared to the B500, the B300 is perfect for smaller spaces while still delivering effective ventilation. This model also boasts a compact design, making it easy to install in tight areas without sacrificing performance.

The B300 features a lightweight but robust construction, which includes sound-insulated components to minimize noise during operation. This is particularly advantageous for residential applications where quiet operation is essential, such as in bedrooms or close to living areas. Users can also take advantage of its user-friendly controls, which parallel those of the B500, ensuring a seamless experience regardless of the model chosen.

Both the B500 and B300 are energy-efficient, designed to comply with modern standards for sustainability. They utilize efficient motors that reduce energy consumption while maximizing airflow, thus benefiting both the environment and reducing utility bills.

Overall, the Air King B500 and B300 provide exceptional ventilation solutions, combining powerful performance with innovative features. Their durability, efficiency, and user-friendly designs make them suitable for a wide range of applications, ensuring that they remain at the forefront of ventilation technology. Whether in a large workshop or a small bathroom, these models stand out for their ability to enhance indoor air quality effortlessly.