![](/images/new-backgrounds/1108357/10835731x1.webp)
Booting OmniSwitch 6850 Series Switches
Booting a Standalone Switch
The OmniSwitch 6850 Series switch does not use an on/off switch. The power cord is the switch’s only connect/discon- nect device. The power connector socket is located on the switch’s rear panel. For more information, refer to the OmniSwitch 6850 Series Hardware Users Guide.
To boot the switch, plug the power cord (provided) into the power connector socket at the switch’s rear panel. Next, plug the power cord into an
The switch immediately begins the boot process. Allow a few moments for the switch to boot completely, then verify the status of all LEDs on the switch’s front panel. A successful boot for a standalone switch displays the following LED states:
LED States for a Standalone Switch
OK | Solid green |
|
|
PRI | Solid green |
|
|
PWR | Solid green |
|
|
LED States for a Standalone Switch
BPS | Solid amber, if BPS attached is failed; |
| off, if no operational BPS is attached; |
| solid green if an operational BPS is |
| attached and operating normally. |
|
|
XFP1 | Off (applies to all OmniSwitch 6850 |
| Series switches except for the |
| OmniSwitch |
| OmniSwitch |
| OmniSwitch |
| OmniSwitch |
| OmniSwitch |
|
|
XFP2 | Off (applies to all OmniSwitch 6850 |
| Series switches except for the |
| OmniSwitch |
| OmniSwitch |
| OmniSwitch |
| OmniSwitch |
| OmniSwitch |
|
|
Slot Indicator | |
| slot number value in the boot.slot.cfg |
| file. See the OmniSwitch 6850 Series |
| Hardware Users Guide for detailed |
| information. The default value is 1. |
|
|
12 Booting OmniSwitch 6850 Series Switches | June 2007 |