BOOT Failures

Activity TE2: Hardware Failure

The ROM diagnostics detected a CSMIM-T1 hardware problem requiring service. Call Technical Support.

Activity TE7: Booted Wrong Image

The CSMIM-T1 loaded an inappropriate image. Press the SETUP button for three seconds to reset the device. Following is a list of ways to prevent this problem in the future:

Be sure that you configure the CSMIM-T1 with the appropriate image (oper.46.enet).

Be sure that the image you are booting has the right name. Don’t rename the image file unless you are making a copy for safe keeping.

If you used an na, admin, or cli boot command, specify the correct image and a valid filename.

5.3BOOT FAILURES

The procedures for troubleshooting a power-up failure established that

The hardware is functional.

The Ethernet interface is functional.

The CSMIM-T1 can communicate with the Ethernet.

If the CSMIM-T1 still is not booted, you must pinpoint the problem. The boot error report can help in this process.

NOTE

The CSMIM-T1generates a boot error report only if it opens the boot file and an error occurs during the boot process.

Generally, two problems cause boot failures:

The CSMIM-T1 is not configured properly.

The load server host is not responding.

CSMIM-T1 Hardware Installation Guide