Cabletron Systems CSMIM-T1 manual Error Description

Models: CSMIM-T1

1 198
Download 198 pages 40.85 Kb
Page 95
Image 95

BOOT Failures

The error count pinpoints the error that caused the boot failure. For example, if the boot failed during a Read Request due to excessive Expedited Remote Procedure Call (ERPC) layer errors, the Errors from Last ERPC Layer Invocation lists only errors that occurred during the failed Read Request (see Table 5-6). The report does not list errors that occurred during any other Read Request (see Table 5-7) or during the Open Request (see Table 5-8).

The Open Request and the Read Request layers communicate with the block file server (BFS) on the host. The ERPC layer resides below the Open Request and the Read Request layers. It is responsible for sending a given message to a specific host UDP port, and for receiving the correct response to that message from the port.

Table 5-6 Errors from Last ERPC Layer Invocation

Error

Description

 

 

H/W errors

The CSMIM-T1 sensed a hardware error during message

 

transmission or reception. This error indicates a fault with the

 

CSMIM-T1 LAN interface. Use the net command to isolate the

 

problem.

Msgs from

The CSMIM-T1 received a message from an incorrect host.

wrong host

This indicates that the CSMIM-T1 received, and ignored, an

 

unsolicited packet.

Rsp T/O’s

The CSMIM-T1 never received a correctly formatted response

 

from the correct host, or any response from any load server

 

hosts.

Msgs of wrong

The correct host sent a message to the CSMIM-T1, but the

type

message was not a correctly formatted response to the

 

transmitted request.

 

 

CSMIM-T1 Hardware Installation Guide

5-11

Page 95
Image 95
Cabletron Systems manual Error Description, Errors CSMIM-T1 sensed a hardware error during message