Chapter 5: Troubleshooting Procedures

5.3.2.4VAX VMS Load Host on the LAN

If the installation was successful and the NCP CIRCUIT SERVICE is enabled, but the CSMIM-T1 still fails to boot, performing the following steps may locate your problem:

1.Make sure that the file CSMIM-T1 OPER_46_ENET.SYS is in the directory MOM$LOAD and the file protection allows reading.

2.Enter the system manager account and enable console logging to see the MOP boot requests, as in the following example:

$reply/enable

$

%%%%%%%% OPCOM 23-DEC-1994 08:3.37 %%%%%%%%

Operator_NTA2: has been enabled, username TOPAZ

$

$

%%%%%%%% OPCOM 23-DEC-1994 08:0.49 %%%%%%%%

Operator status for operator _NTA2:

CENTRAL, PRINTER, TAPES, DISKS, DEVICES, CARDS, NETWORK, CLUSTER, SECURITY, LICENSE, OPER1, OPER2, OPER3, OPER4, OPER5, OPER6, OPER7, OPER8, OPER9, OPER10, OPER11, OPER12

$ WARNING

$

%%%%%%%% opcom 23-DEC-1994 08:03:43.55 %%%%%%%%

Message from user DECNET

DECnet event 0.3, automatic line service

From node 1.69 (BINGO), 23-DEC-1994 08.03.43.52 Circuit SVA-0, Load, requested, Node =2.69 (BART) File = MOM$SYSTEM_SOFTID:OPER_46_ENET.SYS, Operating System

Ethernet address = 00-80-2D-00-1A-DE

$

%%%%%%%% opcom 23-DEC-1994 08:03:50.55 %%%%%%%%

Message from user DECNET

DECnet event 0.3, automatic line service

From node 1.69 (BINGO), 23-DEC-1994 08.03.50.52 Circuit SVA-0, Load, Successful, Node =2.69 (BART) File = MOM$SYSTEM_SOFTID:OPER_46_ENET.SYS, Operating System

Ethernet address = 00-80-2D-00-1A-DE

5-16

CSMIM-T1 Hardware Installation Guide

Page 100
Image 100
Cabletron Systems CSMIM-T1 manual VAX VMS Load Host on the LAN