Cabletron Systems CSMIM-T1 manual S11=n Dtmf Tone Dialing Speed, S12=n Escape Code Guard Time

Models: CSMIM-T1

1 198
Download 198 pages 40.85 Kb
Page 171
Image 171

Registers

S11=n DTMF Tone Dialing Speed

Range: 50 - 100 milliseconds

Default: 75 milliseconds

Sets the length of time after the last tone and before the next tone is sent when the modem is dialing over a touch tone line.

The modem does not store this register with &W; enter *W to save it.

S12=n Escape Code Guard Time

Range: 0 - 255 (fiftieths of a second)

Default: 50 (1 second)

NOTES

Sets the minimum “quiet” time that must be present before and after entering the escape code. The delay between each character in the escape code must be less than this guard time. If register S12 is set to 0, the time it takes to enter the escape code does not affect recognition.

The modem does not store this register with &W; enter *W to save it.

Register S12 sets the guard time that precedes and follows the attention character sequence. It should be set to the same value on both the originating and answering modems.

S14=n Bit Mapped Register

The modem saves the following command settings when you enter them. You do not need to enter &W or *W .

CSMIM-T1 Hardware Installation Guide