Cabletron Systems CSMIM-T1 manual Normal Mode Error Sequence

Models: CSMIM-T1

1 198
Download 198 pages 40.85 Kb
Page 90
Image 90

Chapter 5: Troubleshooting Procedures

5.2.1.2Normal Mode Error Sequence

Table 5-3shows the state of the indicators when an error occurs at various stages of the start-up process. If the CSMIM-T1 fails during the hardware-test state (N2), the error condition is hardware failure NE2. A description of possible causes and solutions for each error condition is in the following paragraphs.

Table 5-3 Normal Mode Error LED States

 

STAT

ATTN

TRAF

Activity

Green

Amber

Green

 

 

 

 

NE2: Hardware Failure

NE5: Booted wrong image

 

 

 

 

Key:

On continuously.

Off.

Flashing irregularly.

Flashing regularly (about 1Hz).

Activity NE2: Hardware Failure

The ROM diagnostics detected a CSMIM-T1 hardware problem requiring service. Call Technical Support.

Activity NE5: Booted Wrong Image

The CSMIM-T1 loaded the wrong image. Press the SET UP button for 3 seconds to reset the device. Following is a list of ways to prevent this problem in the future:

Be sure that you configure the CSMIM-T1 with the appropriate image.

Be sure that the image you are booting has the right name. Don’t rename the image file unless you are making a copy for safe keeping.

If you used an na, admin, or cli boot command, specify the correct image and a valid filename.

5-6

CSMIM-T1 Hardware Installation Guide

Page 90
Image 90
Cabletron Systems CSMIM-T1 manual Normal Mode Error Sequence