Power-Up and Boot Procedures

If you do not know why the CSMIM-T1 booted the wrong image, enter the ROM Monitor mode and issue an image -dcommand. The command display will list the image file the CSMIM-T1 is trying to load.

5.2.2SET UP Mode

Enter SET UP Mode by pressing the SET UP button located on the CSMIM-T1 front panel. Press this button within 30 seconds of resetting or powering up the device.

5.2.2.1SETUP Mode Error-Free Sequence

Table 5-4 summarizes the LED sequences that display in test mode during an error-free start-up. A description of each sequence follows Table 5-4.

Table 5-4 Normal Mode Error LED States

 

STAT

ATTN

TRAF

Activity

Green

Amber

Green

 

 

 

 

T1: Testing Indicators

T2: Testing Hardware

T3: At Monitor Prompt

 

 

 

 

Key:

On continuously.

Off.

Flashing irregularly.

Flashing regularly (about 1Hz).

Activity T1: Testing Indicators

All front panel indicators light for a few seconds, then all but the Ethernet channel indicator turn off. This sequence confirms that all indicators are operational. At this point, the CSMIM-T1 is in normal mode. Press the SET UP button to put the CSMIM-T1 into ROM monitor mode.

CSMIM-T1 Hardware Installation Guide

5-7

Page 91
Image 91
Cabletron Systems CSMIM-T1 manual SET UP Mode, Setup Mode Error-Free Sequence