T-1 Commands

 

Table 4-3 stats-T Command Information

 

 

Field

Description

 

 

Errored

An Errored Second is a second with one or more ESF error

Seconds

events; that is, one or more CRC error events or one or more

 

Out of Frame (OOFs).

Severely

A Severely Errored Second (SES) is a second with 320 or

Errored

more CRC error events or one or more OOF error events.

Seconds

 

Unavailable

Unavailable Seconds (UAS) are a count of one-second

Seconds

intervals during which service is unavailable.

 

 

show t1

The show t1 command displays current T-1 configuration parameters:

The syntax is:

show t1 t1_parameter

set t1

The set t1 command requires superuser privileges, and modifies CSMIM-T1 configuration parameters.

The syntax is:

set t1 t1_parameters

reset

The reset command requires superuser privileges. A reset terminates any active connections.

The reset t1 command resets the T-1 engine and the extended super framing (ESF) statistics. This command is used to change the T-1 engine’s parameter configuration. The T-1 soft, hard, and esf keywords are described in Table 4-4 . The syntax is:

reset t1 [soft hard esf]

CSMIM-T1 Hardware Installation Guide

4-5

Page 73
Image 73
Cabletron Systems CSMIM-T1 manual Reset t1 soft hard esf