Chapter 4: CSMIM-T1 Parameters

4-8 CSMIM-T1 Hardware Installation Guide

4.3 T-1 PARAMETERS

The CSMIM-T1 software comes with the following new T-1 parameters:

Keyword Description
alarmsyslog Sets or displays parameter setting as yes or no. These
values enable or disable the alarm event syslogs.
bypass Sets or displays parameter setting as yes or no. A setting
of yes removes the T-1 engine from the network.
map Sets or displays mappings for the DS0 channels.
ring Sets or displays parameter setting as yes or no. A setting
of yes means that an audible ring is sent to the service
provider for incoming calls.
sigproto Sets or displays the inbound and outbound signaling
protocol settings for each DS0 channel.
t1_info Sets or displays a character string (128 bytes maximum)
of printable ASCII characters that describe installation
information from the service provider.
tni_circuit_id Sets or displays the T-1 circuit identiļ¬er string (128
characters maximum) required by the service provider for
customer service calls.
tni_clock Sets or displays parameter setting as loop, local, or
external. These values represent the source for the T-1
clock.
tni_esf_fdl Sets or displays parameter setting as ansi or att. These
values represent the Facilities Data Link standard.
tni_framing Sets or displays parameter setting as d4 or esf. These
values represent the superframe format setting on the T1
Network Interface.
tni_line_buildout Sets or displays parameter setting as 0, 7.5, 15, or 22.5.
These values represent the cable loss measurement
between the last line generator and the customer location.