Chapter 5: Troubleshooting Procedures

Table 5-7 Errors from Last Read Request

ErrorDescription

Msgs with wrong size The correct host responded to the Read Request, but

 

the data size is incorrect.

ERPC layer errors

See Table 5-6.

Aborts rx’d

The host’s BFS transmitted an abort in response to the

 

CSMIM-T1’s Read Request. Run erpcd –Don the host

 

to obtain more information.

 

Table 5-8 Errors from Last Open Request

 

 

Error

Description

 

 

ARP errors

Address Resolution Protocol (ARP) errors indicate that the

 

CSMIM-T1 is configured to boot from a specified host, but

 

the host would not transmit its Ethernet address to the

 

CSMIM-T1. Possibly, the CSMIM-T1 configuration

 

includes the wrong IP encapsulation.

ERPC layer errors

See Table 5-6

Aborts rx’d

The host’s BFS transmitted an abort in response to the

 

CSMIM-T1’s Open Request. This often means that the

 

requested file does not exist on that server. Run erpcd –D

 

on the host to obtain more information.

 

 

5-12

CSMIM-T1 Hardware Installation Guide

Page 96
Image 96
Cabletron Systems CSMIM-T1 manual ErrorDescription, See Table