BOOT Failures

When the CSMIM-T1 boots in test mode, the console displays the load server host’s Internet address, and indicates whether it receives a response to its Open File Request and to any of its Read File Requests. The host’s progress report indicates receipt of any File Server Requests and its responses to such requests. The host displays erpc_return 0 if it successfully receives a request and is sending out an affirmative response. If any CSMIM-T1-related files are missing or cannot be installed, contact technical support (see Getting Help section in Preface).

A PC host running the UNIX operating system has the erpcd daemon (provided with the distribution and installed in /usr/annex) running in the background on the PC. Set the CSMIM-T1 and the erpcd on the load host into test mode:

1.For erpcd on the load server host, as superuser, kill the erpcd program and restart it using the –D option:

#/usr/annex/erpcd -D5

2.On the CSMIM-T1, hold down the SET UP button for 3 seconds to enter the SET UP mode. Then enter:

monitor:: boot -v

5.3.2.3Another CSMIM-T1

When troubleshooting a CSMIM-T1 configured as a load server host:

1.Use the CLI telnet command to access the unit and verify that it is up and running.

2.Communicate with the unit on the Ethernet using the superuser CLI ping command.

3.Verify the unit’s configuration using na.

The Annex Network Administrator’s Guide provides more information on these commands.

A CSMIM-T1 that has been reconfigured as a load server host, but not rebooted, cannot boot another CSMIM-T1 on the network. Rebooting the CSMIM-T1 load server host ensures that the parameters are set.