Chapter 4: CSMIM-T1 Parameters

Table 4-3 stats-T Command Information

Field

Description

 

 

Online

When illuminated, the T-1 engine is engaged with the

 

network. Otherwise, the T-1 Network Interface and

 

Drop/Insert Interface are isolated from the T-1 engine.

Up Time

Amount of time the T-1 engine has been up, in hours,

 

minutes, and seconds. The “hours” field is a 16-bit register

 

that can count up to 2700 days (less than 7 years).

Serial Number

The T-1 engine’s serial number.

Circuit ID

The T-1 engine’s Circuit ID displayed from the tni_circuit_id

 

parameter.

Unit ID

The T-1 engine’s Unit ID displayed as:

 

“XYLOGICS T1-ENGINE 085nnn Rev. n mm/dd/yy xxxx”

 

Where:

 

085nnn - This is the firmware number.

 

Rev. n - This is the firmware revision number.

 

mm/dd/yy - This is the firmware release date.

 

xxxx - This is the EPROM check sum.

DII Sync

When DII Sync is true, the Drop/Insert Interface is receiving

 

ones pulses and is in frame sync. When DII Sync is false, the

 

Drop/Insert Interface is out of frame sync or not receiving

 

pulses and is sending AIS (all ones framed).

Interval

The 15-minute interval being displayed. This is an integer

 

from 1 to 96, “current” or “total”.

Number of Valid

Part of the “current” report that indicates the number of

Seconds

seconds for which the statistics data has been collected.

Number of

Part of the “total” report that indicates the number of valid

15-minute

15-minute periods. This could also be derived from the

Periods

uptime.

Bursty Errored

A Bursty Errored Second (BES) is a second with more than

Seconds

one, but less than 320 CRC error events.

Controlled Slip

A Controlled Slip Second (CSS) is a second with one or more

Seconds

Controlled Slips.

 

 

4-4

CSMIM-T1 Hardware Installation Guide

Page 72
Image 72
Cabletron Systems CSMIM-T1 manual Drop/Insert Interface is out of frame sync or not receiving