Problem solving guide
Water inlet fault
Problem | Cause and remedy |
One of the following |
|
fault messages appears |
|
in the display: |
|
|
|
Open stopcock | The stopcock is closed. |
| Open the stopcock fully. |
Water intake | Before rectifying the problem: |
| Switch the dishwasher off with the button. |
| The water intake is restricted. |
| Open the stopcock fully and start the programme |
| again. |
| Clean the water inlet filter (see "Maintenance"). |
| The water pressure at the intake is lower than 30 |
| kPa (0.3 bar). |
| Seek professional advice. |
|
|
The following message | The intake water has not reached the required tem‐ |
appears in the display | perature of 45°C (see "Plumbing, Connection to the |
during the SolarSave pro‐ | water supply"). |
gramme: | Start the programme again. |
Intake temp. low | If the fault message appears again, select a differ‐ |
| ent programme. |
|
|
66