Shinco KFR-25GWZ BM Piping length and height difference, Additional refrigerant Charge R410A g

Models: KFR-25GWZ BM KFR-25GWZ BM

1 81
Download 81 pages 63.34 Kb
Page 15
Image 15
6.1 Piping length and height difference

Shinco Service Manual

6.Max. refrigerant piping length and max. height difference

6.1 Piping length and height difference

MODEL

REFRIGERANT PIPING:M

PIPING SIZE O.D:mm

 

 

 

 

 

 

Max. length

Max. Height

Gas

Liquid

 

 

difference

 

 

 

 

 

 

 

KFR-25GWZ/BM

15

5

9.52

6.35

 

 

 

 

 

KFR-35GWZ/BM

15

5

12.7

6.35

KFR-50GWZ/BM

 

 

 

 

 

 

 

 

 

KFR-70GWZ/BM

15

5

9.52

12.88

 

 

 

 

 

6.2 Additional refrigerant Charge (R410A:g)

Model

Outdoor

Refrigerant piping length(one way)

 

 

 

 

 

unit

 

 

 

 

 

 

 

 

 

 

 

 

5m

6m

7m

8m

9m

10m

11m

12m

13m

14m

15m

 

precharge

 

 

 

 

 

 

 

 

 

 

 

 

d(G)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KFR-25GW

840

0

20

40

60

80

100

120

140

160

180

200

Z/BM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KFR-35GW

1130

0

30

60

90

120

150

180

210

240

270

300

Z/BM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KFR-50GW

1300

0

30

60

90

120

150

180

210

240

270

300

Z/BM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KFR-70GW

1900

0

50

100

150

200

250

300

350

400

450

500

Z/BM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 15 -

Page 15
Image 15
Shinco KFR-25GWZ BM service manual Piping length and height difference, Additional refrigerant Charge R410A g