Shinco KFR-25GWZ BM Dehumidifying mode, Compressor frequency on dehumidifying mode, Protection

Models: KFR-25GWZ BM KFR-25GWZ BM

1 81
Download 81 pages 63.34 Kb
Page 48
Image 48
4.4. Dehumidifying mode

Shinco Service Manual

When condenser temperature is higher than 60℃, the compressor will stop, and hen the condenser temperature lower to 50℃ and keep for 5 minutes, and compressor frequency will rise to former value

4.4. Dehumidifying mode

4.4.1 Temperature set and motor control in dehumidifying mode

The compressor and outdoor fan run in dehumidifying mode similar as cooling mode, and the temperature can be set.

The indoor motor speed need to be set in low speed.

4.4.2 Compressor frequency on dehumidifying mode

The maximum frequency in dehumidifying mode is F3,and the frequency changes as following fig.

4.4.3 The louver control in dehumidifying mode

The Louver control in dehumidifying mode is same as cooling mode.

4.4.4 Protection

The Indoor heat exchanger anti-frozen and Outdoor heat exchanger anti-overheat is same as cooling mode.

4.5.Heating mode

4.5.1Compressor frequency controlling a. Frequency control when starting

Temperature difference= Room temperature (RT)-Set temperature (ST)

RT-ST

- 48 -