4.9 Refrigerant charge mode

Shinco Service Manual

4.9 Refrigerant charge mode

Entry condition

Press the emergency switch over 5 seconds, there will be three “DU” sound in the indoor unit, and start the unit with the remote controller.

Actions

1.On cooling mode, the indoor fan speed is low the frequency is fixed on F6,

2.Cancel the mode

Turn off the air conditioner with remote controller

5. Protection

5.1 Compressor protection

5.1.1 High pipe discharge temperature protection

When discharge pipe temperature is higher than T3, the compressor frequency will be lowered, when discharge pipe temperature lower to T1, the frequency will rise, and the frequency will be limited one class than former one. When the discharge pipe temperature lower to T2 and keep for 10 minutes, the frequency will return to former one.

When discharge pipe temperature is higher than T4, the compressor stop and the outdoor motor stop 15s later. When discharge pipe temperature lower to T1 and the unit restart after 3 minutes.

 

T1

T2

T3

T4

 

 

 

 

 

KFR-25GWZ/BM

 

 

 

 

 

 

 

 

 

KFR-35GWZ/BM

 

 

 

 

 

90

95

105

110

KFR-50GWZ/BM

 

 

 

 

 

 

 

 

 

KFR-70GWZ/BM

 

 

 

 

 

 

 

 

 

5.1.2 Sensor protection

There is thermal sensor on compressor, and the compressor will stop when the temperature is too high, and the outdoor motor will stop 15s later. When the temperature return normal value, the compressor will restart 3 minutes later.

5.1.3 Compressor relay start protection

The compressor will restart 3 minutes after stop.

5.2 Current protection

When outdoor current is higher than I1, the compressor frequency will be limited and prohibited to rise. When the current is higher than I2, and the compressor frequency will lower until the current is lower than I1.

When outdoor current is lower than I3, the compressor will stop.

The detailed current value see below table:

- 51 -