Shinco Service Manual
| MODE | I1 | I2 | I3 |
|
|
|
|
|
| COOLING AND DEHUMIDIFYING | 7.1 | 8.3 | 10.3 |
|
|
|
|
|
| HEATING | 6.3 | 7.5 | 9.5 |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| MODE | I1 | I2 | I3 |
|
|
|
|
|
| COOLIGN AND DEHUMIDIFYING | 8.1 | 9.6 | 11.6 |
|
|
|
|
|
| HEATING | 10.5 | 12 | 14 |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| MODE | I1 | I2 | I3 |
|
|
|
|
|
| COOLING AND DEHUMIDIFYING | 8.5 | 10.5 | 12.5 |
|
|
|
|
|
| HEATING | 8.5 | 10.5 | 12.5 |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| MODE | I1 | I2 | I3 |
|
|
|
|
|
| COOLIGN AND DEHUMIDIFYING | 12 | 16 | 18 |
|
|
|
|
|
| HEATING | 14 | 19 | 21 |
|
|
|
|
|
5.3 Low voltage protection
The compressor frequency changes as following fig. during low voltage:
When voltage value lower than 190V and keep for 10s, the low voltage protection start, and when voltage value rise to 195V and keep for 10s, the low voltage proteccion finish.
When voltage value lower than 158V, the unit turn off, when voltage rise to 162V, keep for 10s, the unit restart.
- 52 -