Allegro Multimedia Continuous-Time Ratiometric Linear Hall Effect Sensors, A1301 and A1302

Models: A1301 A1302

1 8
Download 8 pages 11.54 Kb
Page 3
Image 3
Characteristic

A1301 and

A1302

Continuous-Time Ratiometric Linear Hall Effect Sensors

DEVICE CHARACTERISTICS over operating temperature range, TA, and VCC = 5 V, unless otherwise noted

Characteristic

Symbol

Test Conditions

Min.

Typ.

Max.

Units

Electrical Characteristics

 

 

 

 

 

 

Supply Voltage

 

 

VCC

Running, TJ < 165°C

4.5

6

V

Supply Current

 

 

ICC

Output open

11

mA

Output Voltage

 

 

VOUT(High)

ISOURCE = –1 mA, Sens = nominal

4.65

4.7

V

 

 

VOUT(Low)

ISINK = 1 mA, Sens = nominal

0.2

0.25

V

 

 

 

Output Bandwidth

 

BW

 

20

kHz

Power-On Time

 

 

tPO

VCC(min) to 0.95 VOUT; B = ±1400 G;

3

5

μs

 

 

Slew rate = 4.5 V/μs to 4.5 V/100 ns

Output Resistance

 

ROUT

ISINK ≤ 1 mA, ISOURCE –1 mA

2

5

Ω

Wide Band Output Noise, rms

VOUTN

External output low pass filter ≤ 10 kHz;

150

μV

Sens = nominal

Ratiometry

 

 

 

 

 

 

 

 

Quiescent Output Voltage Error

ΔVOUTQ(V)

TA = 25°C

±3.0

%

with respect to ΔV

1

 

CC

 

 

 

 

 

 

 

Magnetic Sensitivity Error with

ΔSens(V)

TA = 25°C

±3.0

%

respect to ΔV

2

 

CC

 

 

 

 

 

 

 

Output

 

 

 

 

 

 

 

 

Linearity

 

 

Lin

TA = 25°C

±2.5

%

Symmetry

 

 

Sym

TA = 25°C

±3.0

%

Magnetic Characteristics

 

 

 

 

 

 

Quiescent Output Voltage

VOUTQ

B = 0 G; TA = 25°C

2.4

2.5

2.6

V

Quiescent Output Voltage over

VOUTQ(ΔTA)

B = 0 G

2.2

2.8

V

Operating Temperature Range

Magnetic Sensitivity

 

Sens

A1301; TA = 25°C

2.0

2.5

3.0

mV/G

 

A1302; TA = 25°C

1.0

1.3

1.6

mV/G

 

 

 

 

Magnetic Sensitivity

over

Sens(ΔTA)

A1301

1.8

3.2

mV/G

Operating Temperature Range

A1302

0.85

1.75

mV/G

 

1Refer to equation (4) in Ratiometric section on page 4. 2Refer to equation (5) in Ratiometric section on page 4.

Allegro MicroSystems, Inc.

3

115 Northeast Cutoff, Box 15036

Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com