A1321, A1322, and A1323

Ratiometric Linear Hall Effect Sensor for High-Temperature Operation

MAGNETIC CHARACTERISTICS1,2 over operating temperature range, TA; VCC = 5 V, Iout = –1 mA; unless otherwise noted

Characteristics

Symbol

Test Condition

Min

Typ3

Max

Units4

Sensitivity5

 

Sens

A1321; TA = 25ºC

4.750

5.000

5.250

mV/G

 

A1322; T = 25ºC

2.969

3.125

3.281

mV/G

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

A1323; TA = 25ºC

2.375

2.500

2.625

mV/G

Delta Vout(q) as a func-

Vout(q)(ΔT)

Defined in terms of magnetic flux density, B

±10

G

tion of temperature

Ratiometry, Vout(q)

Vout(q)(ΔV)

 

±1.5

%

Ratiometry, Sens

ΔSens(ΔV)

 

±1.5

%

Positive Linearity

Lin+

 

±1.5

%

Negative Linearity

Lin–

 

±1.5

%

Symmetry

 

Sym

 

±1.5

%

UA Package

 

 

 

 

 

 

 

 

 

Delta Sens at T

= max5

ΔSens

(TAmax)

From hot to room temperature

–2.5

7.5

%

A

 

 

 

 

 

 

 

Delta Sens at T

= min5

ΔSens

(TAmin)

From cold to room temperature

–6

4

%

A

 

 

 

 

 

 

 

Sensitivity Drift6

 

Sens

Drift

T = 25°C; after temperature cycling and over time

±2

%

 

 

 

 

A

 

 

 

 

LH Package

 

 

 

 

 

 

 

 

 

Delta Sens at T

= max5

ΔSens

(TAmax)

From hot to room temperature

–5

5

%

A

 

 

 

 

 

 

 

Delta Sens at T

= min5

ΔSens

(TAmin)

From cold to room temperature

–3.5

8.5

%

A

 

 

 

 

 

 

 

Sensitivity Drift6

 

Sens

Drift

T = 25°C; after temperature cycling and over time

±2

%

 

 

 

 

A

 

 

 

 

1Additional information on chracteristics is provided in the section Characteristics Definitions, on the next page.

2Negative current is defined as conventional current coming out of (sourced from) the specified device terminal.

3Typical data is at TA = 25°C, except for ΔSens, and at x.x Sens. Typical data are for initial design estimations only, and assume optimum manufacturing and application conditions. Performance may vary for individual units, within the specified maximum and minimum limits. In addition, the typical values vary with gain.

410 G = 1 millitesla.

5After 150ºC pre-bake and factory programming.

6Sensitivity drift is the amount of recovery with time.

Allegro MicroSystems, Inc.

4

115 Northeast Cutoff

Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com

Page 4