A1321, A1322, and A1323
Ratiometric Linear Hall Effect Sensor for
MAGNETIC CHARACTERISTICS1,2 over operating temperature range, TA; VCC = 5 V, Iout =
Characteristics | Symbol | Test Condition | Min | Typ3 | Max | Units4 | |||
Sensitivity5 |
| Sens | A1321; TA = 25ºC | 4.750 | 5.000 | 5.250 | mV/G | ||
| A1322; T = 25ºC | 2.969 | 3.125 | 3.281 | mV/G | ||||
|
|
|
|
| A |
|
|
|
|
|
|
|
|
| A1323; TA = 25ºC | 2.375 | 2.500 | 2.625 | mV/G |
Delta Vout(q) as a func- | Vout(q)(ΔT) | Defined in terms of magnetic flux density, B | – | – | ±10 | G | |||
tion of temperature | |||||||||
Ratiometry, Vout(q) | Vout(q)(ΔV) |
| – | – | ±1.5 | % | |||
Ratiometry, Sens | ΔSens(ΔV) |
| – | – | ±1.5 | % | |||
Positive Linearity | Lin+ |
| – | – | ±1.5 | % | |||
Negative Linearity | Lin– |
| – | – | ±1.5 | % | |||
Symmetry |
| Sym |
| – | – | ±1.5 | % | ||
UA Package |
|
|
|
|
|
|
|
|
|
Delta Sens at T | = max5 | ΔSens | (TAmax) | From hot to room temperature | – | 7.5 | % | ||
A |
|
|
|
|
|
|
| ||
Delta Sens at T | = min5 | ΔSens | (TAmin) | From cold to room temperature | – | 4 | % | ||
A |
|
|
|
|
|
|
| ||
Sensitivity Drift6 |
| Sens | Drift | T = 25°C; after temperature cycling and over time | – | ±2 | – | % | |
|
|
|
| A |
|
|
|
| |
LH Package |
|
|
|
|
|
|
|
|
|
Delta Sens at T | = max5 | ΔSens | (TAmax) | From hot to room temperature | – | 5 | % | ||
A |
|
|
|
|
|
|
| ||
Delta Sens at T | = min5 | ΔSens | (TAmin) | From cold to room temperature | – | 8.5 | % | ||
A |
|
|
|
|
|
|
| ||
Sensitivity Drift6 |
| Sens | Drift | T = 25°C; after temperature cycling and over time | – | ±2 | – | % | |
|
|
|
| A |
|
|
|
|
1Additional information on chracteristics is provided in the section Characteristics Definitions, on the next page.
2Negative current is defined as conventional current coming out of (sourced from) the specified device terminal.
3Typical data is at TA = 25°C, except for ΔSens, and at x.x Sens. Typical data are for initial design estimations only, and assume optimum manufacturing and application conditions. Performance may vary for individual units, within the specified maximum and minimum limits. In addition, the typical values vary with gain.
410 G = 1 millitesla.
5After 150ºC
6Sensitivity drift is the amount of recovery with time.
Allegro MicroSystems, Inc. | 4 |
115 Northeast Cutoff
Worcester, Massachusetts