AllerAir manual FILTER ASSEMBLY- 600 D, DX, Step, Model 600 Series

Models: 600 Series

1 2
Download 2 pages 14.36 Kb
Page 1
Image 1
FILTER ASSEMBLY- 600 D, DX

FILTER ASSEMBLY- 600 D, DX

Step 1

Turn Power Off and unplug receptacle.

Lay unit upside down.

Step 4

Remove only one of the white, felt, donut-shaped gaskets from the inside of the purifier body.

Step 2

With a #2 Philips screw driver, remove the four screws from the bottom of the unit.

Step 5

Insert the carbon filter (either a Model 600 D Carbon or a Model 600 DX Carbon) into the unit.

Step 3

Gently grasp wheels.

Remove base by gently pulling on the wheels.

Step 6

Replace the gasket that had been removed in STEP 4.

Step 7

Place lid back to its proper position by aligning the arrow with the rear seam.

Step 8

Replace the four screws

Step 9

Turn the unit back onto its wheels. It is now ready for immediate use.

Step 1 Model 600 Series

Operation and Maintenance Manual

AllerAir Industries Inc. Toll free: 1-888-852-8247 / Fax: 1-877-688-3939 www.allerair.com