The majou cause of problems with acoustic performance and skipping on the vinyl is the lack of proper set up of the needle and turntable adjustments. The needle is designed to operate at a specific angle to the vinyl. The T.55 USB has several adjustments to correctly position the needle to the vinyl!

1. The first adjustment is the installation of the cartridge-headshell assembly into the tone arm tube lock. The

 

 

 

T.55 USB includes a Stanton 500 V3 cartridge pre-mounted to the headshell. Holding the tone arm tube in one

 

 

hand, insert the cartridge-headshell into the tube lock with the other hand. Turn the lock ring clockwise (when

 

 

viewed from the rear) until the headshell is locked tightly into the tone arm. Remove the needle protector from

 

 

Locking Ring

the cartridge and place the needle on record. View the needle from the front and insure that the needle is

 

 

 

perpendicular to the record surface. If some adjustment is needed, simply loosen the lock ring and rotate the

 

 

 

cartridge headshell until the needle is perpendicular to the record surface. Then re-tighten the lock ring.

 

 

 

 

 

 

1

2. The second adjustment is the needle (or stylus) pressure. Start with the cartridge headshell

 

 

 

assembly mounted into the tone arm. Remove any needle protectors provided. With tone arm

 

 

 

free, adjust the tone arm counterweight by rotating the rear section until the tone arm floats in a

 

 

Rear Section

balanced condition above the record or mat. Do not allow the needle to drop onto the mat or the

2.0

1

 

turntable platter during this adjustment. You might damage the needle tip. Now, carefully hold

 

.0

 

 

 

Numbered Ring

the tone arm in one hand while rotating the numbered ring on the front of the counter-weight

 

0

 

 

 

with the other hand to the “0” setting. Next, without touching the numbered ring, Rotate the rear

 

 

 

counterweight until the desired needle pressure reading is next to the line on top of the tone

 

 

 

arm tube. The recommended stylus pressure for the Stanton 500 V3 cartridge is between two

 

 

 

and five grams.

 

 

2

 

 

 

OPERATIONS

1.Rotate the power dial clockwise to turn on the power. The speed indicator and the strobe-illuminator will light up.

2.Place a record on the slip mat, when playing a 45rpm record with a large center hole, place the 45-rpm adaptor on the center spindle.

3.Set the rotation speed (33/45) to match the record.

4.Remove the stylus protector, release the arm clamp.

5.Press the Start/Stop button, the turntable platter will start to rotate.

6.Move the tonearm over the desired groove.

7.When play is finished, move the tonearm to the arm rest, secure the tonearm with the arm clamp.

8.Press the Start/Stop button to stop the platter rotating and rotate the power dial to turn off the power.

MAINTENANCE

-For best results & proper care of your equipment use Stanton Vinyl Cleaner (VC-1) for your records and Stylus Cleaner Kit for styli (SC-4).

-Clean the stylus periodically with a soft brush to prevent the accumulation of dust.

-When the sound becomes distorted or noisy, check the stylus. If worn out, replace it with a new one.