Operating Instructions
Error Codes
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:•Disconnect electric power to the tumbler before servicing.•Close gas•Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.
|
| W002 |
|
|
|
|
|
|
Display | Definition | Corrective Action |
|
|
|
| Open thermistor error | • Check thermistor. Replace if inoperative. |
|
| • Check wiring diagram between control and |
OP |
| thermistor. Refer to wiring diagram for proper |
|
| wiring. |
|
| • Check control. Replace if inoperative. |
|
|
|
| Shorted thermistor error | • Check thermistor. Replace if inoperative. |
SH |
| • Check wiring between control and thermistor. |
| Refer to wiring diagram for proper wiring. | |
|
| |
|
| • Check control. Replace if inoperative. |
|
|
|
AF - 1 | Airflow switch closed when cycle | • Check airflow switch. Replace if inoperative. |
started |
| |
|
| |
|
|
|
AF - 2 | Airflow switch failed to close after | • Check airflow switch. Replace if inoperative. |
cycle started |
| |
|
| |
|
|
|
10 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 70400101 |