Operating Instructions
25C
Figure 4
Single Drop Control
SD and SX Control Suffixes
1.Select HIGH, MED, LOW or NO HEAT by turning the temperature knob.
2.Insert the coin(s) in the coin slot.
3.Press START button to start tumbler.
IMPORTANT: To stop the tumbler at any time during the cycle, OPEN DOOR. To restart the tumbler, CLOSE door and press START button.
NOTE: If display show an error code, refer to Error Codes section.
4.When the cycle is complete, open door and remove the laundry.
NOTE: This machine includes an extended tumble feature. Starting 20 minutes after a cycle ends, the cylinder will tumble for two minutes every hour without heat, up to 18 hours or until door is opened.
Preliminary Control Information
Power-Up Mode
When power is applied to the tumbler the control will enter Ready Mode, unless a cycle was in process prior to a disruption of power. If a power disruption is less than 5 seconds, with a cycle in process, the control will enter Run Mode once power is restored and continue the cycle. If a power disruption is more than 5 seconds, with a cycle in process, the control will enter Start Mode once power is restored.
If the dry time dipswitch settings have not changed from the factory default, the IN USE LED will flash two to five times, depending on model.
Ready Mode
In Ready Mode, the control waits for the vend to be satisfied before entering Start Mode.
Start Mode
In Start Mode, the vend has been satisfied, but the Start button has not been pressed. The IN USE LED will be lit. The timer will not count down until the Start button is pressed.
70400101 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 11 |