Programming

Setup Mode (Continued)

To enter setup mode, press the Stop key while the display is showing the temperature in the sump. Once in setup mode, use the Up or Down key to change the selected option. Use the Start key to accept the selected option and move on to the next one. Press the Stop key to exit setup mode.

Degrees Displayed in Fahrenheit

or Celsius

This setup option affects the programming and display of all temperatures. If “FAr”

is selected, all temperatures will display in Fahrenheit. If “CEL” is selected, all temperatures will display in Celsius. Acceptable ranges for programmable temperatures are 75°F–200°F or 25°C–93°C.

Auxiliary Heat

Heat is a dedicated output of the V-computer, which controls an optional heat source. If “noHt” is selected, the heat output will never energize during a cycle (except briefly in the test cycle to ensure that the output functions properly). If “HEAt” is selected, the output will energize during a cycle if the three following conditions are true:

A nonzero heat temperature is programmed.

The computer senses that the present temperature is below the programmed target temperature.

At least a low water level is present in the machine.

22

Note: Do not enable the auxiliary heat setup option on machines not equipped with auxiliary heat. The machine will pause for

30 minutes during any cycle segment where the fill water temperature does not equal or exceed the programmed value of the heat step.

Setting Display to Flash “PAY” and a Start Amount

If the display is programmed to flash “PAY” and a start amount, it will read “FLSH.” Otherwise the display will read “nFLS.” Press the Up or Down key to change from one to the other.

Programming Start Price

The display will read “Strt” for one second, followed by “A nt” for one second, then the programmed start price. For example, if the start price is $1.50, the display will read “150” for start price.

Press the Up key to increase the start amount, or the Down to decrease the start amount.

Note: When using the Up or Down key to increase or decrease the start amount, holding the key down for several seconds will cause the displayed value to change more rapidly.

F232061