Programming
Cycle Programming (Continued)
When modifying a cycle, a time must be entered for each segment. To skip a segment or spin, set the time to “00” and press the Start key. The following table gives the time parameters for each segment and spin, as well as the allowable temperature range.
Time and Temperature Parameters
Function | Minimum | Maximum | |
|
|
|
|
Prewash | 2 minutes | 30 minutes | |
|
|
|
|
Wash | 2 minutes | 20 minutes | |
|
|
|
|
Fill 1 | 2 minutes | 15 minutes | |
|
|
|
|
Fill 2 | 2 minutes | 15 minutes | |
|
|
|
|
Fill 3 | 2 minutes | 15 minutes | |
|
|
|
|
Fill 4 | 2 minutes | 15 minutes | |
|
|
|
|
Fill 5 | 2 minutes | 15 minutes | |
|
|
|
|
Fill 6 | 2 minutes | 15 minutes | |
|
|
|
|
Intermediate Spin | 30 seconds | 240 seconds | |
|
|
|
|
Final Spin | 1 minute | 10 minutes | |
|
|
|
|
Temperature | 75°F (25°C) | 200°F (93°C) | |
|
|
|
|
|
|
|
|
|
|
|
|
Note: Spin times in cycle segments
1.Press the Up key until the computer display shows the segment to be edited. Press the Start key.
2.Use the Up or Down key to select the desired segment time. Set this value to zero to skip the segment. Press the Start key.
24
3.Use the Up or Down key to select the desired fill temperature. See the following table for fill options.
Fill Temperature Options
Display | Fill Type |
|
|
CFIL | Cold fill |
|
|
HFIL | Hot fill |
|
|
bFIL | Warm fill |
|
|
AFIL | Auxiliary fill* |
|
|
*Controls filling via an extra fill valve for special applications only. Do not program this option unless machine is equipped with extra fill valve.
4.Press the Start key.
5.Use the Up or Down key to select the desired fill level. See the table below.
Water Level Options
Display | Fill Level |
|
|
LO | Low Level |
|
|
ned | Medium Level |
|
|
HI | High Level |
|
|
6.Press the Start key.
7.Use the Up or Down key to select the desired supply option. See the table below.
Note: If as supply 2 (SUP2) step is programmed, the display will flash “bLCH” (add bleach) while supply 2 is on when the cycle is in operation.
F232061