Coin 1 Denomination

The display will read “Con1” for one second, “dEno” for one second, then the coin 1 denomination. For example, if coin 1 is a quarter, the display will read “25” for coin 1 denomination.

Press the Up key to increase the denomination, or the Down key to decrease the denomination.

Coin 2 Denomination

The display will read “Con2” for one second, “dEno” for one second, then the coin 2 denomination. For example, if coin 2 is a quarter, the display will read “50” for coin 2 denomination.

Press the Up key to increase the denomination, or the Down key to decrease the denomination.

Note: The “Con2” setting has no effect on models equipped with a single coin acceptor.

Programming

Cycle Programming

To edit an existing cycle or create a new cycle, press the Up key while the display is showing the temperature in the sump. The display will show “CY01.” Press the Up or Down key until the desired cycle number is displayed. Press the Start key to begin editing the selected cycle.

Segment Programming

All cycle programs (“CY1”–“CY16”) can be customized within a preset program structure. Each cycle program consists of eight program segments. See the following table.

Cycle Program Segments

Segment

Display

Segment

Display

 

 

 

 

Prewash

PrE

Fill 3

FIL 3

 

 

 

 

Wash

UASH

Fill 4

FIL 4

 

 

 

 

Fill 1

FIL 1

Fill 5

FIL 5

 

 

 

 

Fill 2

FIL 2

Fill 6

FIL 6

 

 

 

 

Cycle Count

To display the current cycle count, press the Start key while the display is showing the temperature in the sump. The display will show a two-digit number indicating how many cycles have been run to completion (cycles which were stopped in progress are not counted). Press the Start key to return to program mode without resetting the count.

Press the Stop key to reset the count to zero and return to program mode.