Maintenance

Monthly

NOTE: Disconnect power to the machine at its source before performing the monthly maintenance procedures.

1.Clean the AC drive Box.

a.Remove the AC drive box cover.

b.Blow the fins clean using compressed air at a pressure of 60-90 psi or by using canned compressed air. Use care to avoid damaging cooling fan or other components.

2.Belts.

a.Check belts for uneven wear and frayed edges.

b.Verify that belts are properly aligned by checking pulley alignment. Place a straightedge across both pulley faces. The straightedge should make contact with the pulleys in four places.

3.If a machine frequently skips the final spin, check whether the probe of the out of balance switch is still in the appropriate position, that is horizontally centered and vertically 1/3 from the bottom inside the window (when the drum is empty). (See electronic repetition system.)

4.Clean drain pipe.

The water still being in the drain needs to be drained using drain (A) before cleaning the drain pipe or replacing the exhaust valve. Refer to Figure 7.

A

CFD27N

ADrain

Figure 7

5.Remove back panel and check overflow hose and drain hose for leaks.

6.Clean inlet hose filter screen:

a.Turn water off and allow valve to cool, if necessary.

b.Unscrew inlet hose and remove filter screen.

c.Clean with soapy water, rinse and reinstall. Replace if worn or damaged.

7.Check the supply dispenser hoses for leaks.

8.Use compressed air to clean lint from motor.

9.Clean interior of machine, both basket and shell, by wiping with a water-soaked sponge or cloth.

10.Use compressed air to ensure that all electrical components are free of moisture and dust.

11.Verify that insulation is intact on all external wiring and that all connections are secure. If bare wire is evident, call a Service Technician.

Yearly

Check if the machine is working properly. If you see or hear any abnormal function on the machine call a service technician.

14

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

9001910