Maintenance
4.Remove back panel and check overflow hose and drain hose for leaks.
5.Unlock the hinged lid and check the supply dispenser hoses and hose connections.
6.Clean inlet hose filter screens:
a.Turn water off and allow valve to cool, if necessary.
b.Unscrew inlet hose and remove filter screen.
c.Clean with soapy water and reinstall. Replace if worn or damaged.
7.Tighten motor mounting bolt locknuts and bearing bolt locknuts, if necessary.
8.Use compressed air to clean lint from motor.
9.Use compressed air to ensure that all electrical components are free of moisture and dust.
10.Verify that the insulation is intact on all external wires and that all connections are secure. If bare wire is evident, call a service technician.
Quarterly
NOTE: Disconnect power to the machine at its source before performing the quarterly maintenance procedures.
1.Tighten door hinges and fasteners, if necessary.
2.Using a
3.Verify that the drain motor shield is in place and secure, if so equipped.
4.Check all painted surfaces for exposed metal. (Matching paint is available from the manufacturer.)
●If bare metal is showing, paint with primer or with a
●If rust appears, remove it with sandpaper or by chemical means and then paint the affected area with primer or with a
5.Clean supplied steam filter, where applicable. Refer to Figure 12.
a.Turn off steam supply and allow time for the valve to cool.
b.Unscrew Cap.
c.Remove Element and clean.
d.Replace Element and Cap.
1
2
H042I
H042I
1Cap
2Filter Element
Figure 12
6.Measure the
7.Check the bearing mounting bolts to make sure they are torqued properly. Refer to Table 3 for specifications.
Machine | Bearing | Torque | |
Capacity | |||
|
| ||
|
|
| |
125 | Front | 500 | |
|
|
| |
125 | Rear | 140 | |
|
|
|
Table 3
18 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232215 |