Safety
The following table lists the various displays and what they mean. The operator should become familiar with these computer displays.
Display Indications
Display | Meaning | Display | Meaning | |
Program identification code (ROM) | bFIL | Warm fill (both hot and cold) | ||
This is an example only. | ||||
|
|
| ||
|
|
|
| |
Hold | Wait...power has just been turned on. | HFIL | Hot fill | |
|
|
|
| |
CY | Cycle (followed by | LOLE | Low water level | |
|
|
|
| |
CHEC/CYC* | Test cycle selected. | HILE | High water level | |
|
|
|
| |
FAr | Degrees Fahrenheit | SUP1 | Supply 1 | |
|
|
|
| |
CEL | Degrees Celsius | SUP2 | Supply 2 | |
|
|
|
| |
PrE | Prewash segment (1st of 8 segments) | SUP3 | Supply 3 | |
|
|
|
| |
UASH | Wash segment (2nd of 8 segments) | SUP4 | Supply 4 | |
|
|
|
| |
FIL1 | First rinse (3rd of 8 segments) | SUP5 | Supply 5 (supply 1 and 2) | |
|
|
|
| |
FIL2 | Second rinse (4th of 8 segments) | SUP6 | Supply 6 (supply 2 and 3) | |
|
|
|
| |
FIL3 | Third rinse (5th of 8 segments) | SUP7 | Supply 7 (supply 3 and 4) | |
|
|
|
| |
FIL4 | Fourth rinse (6th of 8 segments) | STOP | Stop routine | |
|
|
|
| |
FIL5 | Fifth rinse (7th of 8 segments) | SdLY | Spin coast delay | |
|
|
|
| |
FIL6 | Sixth rinse (8th of 8 segments) | donE | Cycle and stop routine have ended. | |
|
|
|
| |
CFIL | Cold fill | door | Door not properly closed. | |
|
|
|
| |
SPIn/tIME* | Reads “SPIn” for one second, then | FILL/STOP* | Programmed water level not reached after 30 | |
“tIME” followed by time for spin. | minutes. | |||
|
| |||
|
|
|
| |
tSFL | Temperature sensor failure or temperature | FULL | The computer detects low water level or higher | |
out of range. | when none should be present. | |||
|
|
*Display indications separated by a slash represent an alternating display.
F232073 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 15 |